UTL 2KVA 48V Gamma PCU
Gamma Solar PCU
The Gamma solar PCU (Power Conditioning Unit) is rMPPT offline solar PCU one phase in one phase out. It is very affordable for schools, hospitals, petrol pumps, industries, and buildinds and also for home. The Gamma Solar PCU (rMPPT) is uses the solar power energy in first priority and the government electricity (grid) in second priority to charge the solar batteries.
Technical Specfication
Description Particulars Solar PCU Capacity 2KVA 48V Input Voltage Range (min-max) 80-230 VDC Maximum PV Power Recommended 2KW Types of Charger PWM with MPPT Charge Controller Peak Efficiency 95% Battery Low Buzzer 10.2V Battery Low Cut 10.0V Battery High Cut 15.5V Battery Charging Voltage by SPV 14.5V Battery Charging Current by SPV 18A Battery Charging Voltage by GRID 14.2V Battery Charging Current by GRID 10A Grid Low Cut Voltage ( IT Load Disable/Enable) 120/175V Grid High Cut Voltage ( IT Load Disable/Enable) 280/255V Inverter Nominal Output Voltage 230VAC Output Supply Phase 1 phase, 3 wire Output Waveform Sine wave Nominal Frequency 50.0 HZ Load Current 6.1 A Inverter Peak Efficiency >88% Protections Overload, Battery low, Battery high, Output low, Output high, Output Short Circuit, Overheat, Under Frequency, Over Frequency, Solar panel reverse Display Parameters Battery Voltage, Charging Current, Discharging Current* Solar Voltage, Solar Current, Instantaneous Power, Grid Voltage, I/P Frequency Output Voltage, Output Load% O/P Frequency Grid, Inverter & SPV Charger Status Switches Reset for System ON/OFF, up, Down, Back, Enter (for LCD Configuration) Indications System ON, Inv. ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under frequency, Over frequency, (IT Mode, Grid Charging, NLSD, Boost Charging, DG Mode)Enable/Disable* Max Relative Humidity @25*C (non condensing) 95% Weight 27KG Dimension (L X W X H) 381 X 279 X 355 mm Product Description
Unique Features
- DSPic Based Pure Sine Wave Design.
- Inbuilt rMPPT Charge Controller (30% more efficient).
- Maximum Power Preference to Solar Energy.
- Digital LCD (16X2) Display.
- Priority Based Working Modes - Smart/PCU/Hybrid.
- Reverse AC Voltage Protection.
- Robust Design-20 years Product Life, 2-5 years of warranty.
Special Features
Solar Battery for Long Life
The solar battery fitted in gamma solar PCU feeds to it at a constant boost charging current until its voltage reaches 14.2V and the float current (which is very close to zero) then maintains this voltage above 13V. Thus reducing the float current (flowing for the longest period during the entire process) becomes zero, which ultimately results in greatly increased battery life and is fully charged simultaneously.
Extensive electronic protection
Gamma Solar PCU which ensures safety, it prevents reverse flow from battery to solar array, it provides load short circuit protection, it provides solar battery through DC fuse, overload protection, input low or high, output low / high or solar panel provides reverse protection.
Utilizes maximum power available from the solar panel
The gamma solar PCU senses the point of maximum power available in the solar panel and charges the battery with this maximum power. Therefore, at any given time the battery is charged with the maximum possible power.
LCD display
It has an LCD display for better user interface that displays battery voltage, current charge, current discharging current, output voltage, output frequency, output load percentage, input voltage, input frequency, solar voltage, solar current and solar energy.