ALFA+ Solar PCU UTL 15KVA 240V Alfa+ PC
We are introducing an advanced ALFA+ Solar PCU that is mainly used in Hospitals, schools, industries petrol pumps, banks and also in home. PCU means Power Conditioning Unit, is an integrated unit consists of grid charger, inverter, MPPT solar charger. Alfa + solar PCU continuously monitor battery and solar voltage as well as grid and output voltage with their current.
MPPT based solar charge controller extracts the maximum power from the solar panel whereby it increases the efficiency of the system. In Alfa+ Solar PCU MPPT charger has multi stage charging which maintains the battery charging voltage such that it increases the life of solar battery.
ALFA+ Solar PCU
PCU means Power Conditioning Unit which uses solar power energy in first priority and grid (government electricity) in second priority to charge the solar batteries. Since usage of power from grid in Alfa+ Solar PCU is secondary, grid power is only used when solar energy isn't present and battery voltage level reduces to 11.5V/Battery (Default 11.5V, Configurable). Grid power is also needed when solar power generation is less and battery voltage is reduced to 11.5V/Battery (Default 11.5V, Configurable).
Technical Specfication
Particulars Description Solar PCU Capacity 15KVA 240V Input Voltage Range (Min-Max) 400-750 VDC Maximum PV Power Recommended 15KW MPPT Controller DSP Type of Charger MPPT Efficiency 95% Battery Low Buzzer Battery Low Cut +0.2 V Battery Low Cut 10-11.7 V Battery High Cut (INV.) SPV Present-SPV CHG. REF +1V for 15Sec, SPV CHG. REF +1.5V for 2Sec Battery High Cut (INV.) SPV Absent-SPV CHG. REF for 15Sec, SPV CHG. REF +0.2V for 2Sec Battery Charging Voltage by SPV 13.5-16 V Battery Charging Current by SPV 12-60 A Battery Charging Voltage by Grid 13.0-15.5 V Battery Charging Current by Grid 6-15 A Grid Low Cut Voltage (IT Mode/Normal) NA/120-200 V Grid High Cut Voltage (IT Mode/Normal) NA/245-280 V Grid Charging Enable/Disable IT Load Enable/Disable Operating Mode Smart/PCU/Hybrid Output Voltage Low 170-190 V Output Voltage High 250-260 V No Load Shut Down Enable/Disable Input Source Grid/Genset Grid Disconnect (Solar Available) PCU/SMART (Battery) @14.5/Battery for 2minutes or 13.5/Battery-100% Current Grid Reconnect (PCU Mode/Smart Mode) (Battery) 11-12V Temp. Compensation (Battery) @3mV/cell/°C ; 18mV/Battery/°C Inverter Switching Element Mosfet Inverter Control PWM Inverter Nominal Output Voltage 220 VAC Inverter Output Supply Phase 1Phase, 3Wire Inverter Output Waveform Pure Sine Wave Inverter Nominal Frequency 50.0 Hz Load Current 54 A Voltage Regulation 1% Output Voltage Distortion with 100% Linear Load <3% Peak Efficiency >88 % Cooling Temp Controlled, Fan Protections Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse Display Parameters Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency NLSD En/Dn, IT Load En/Dn Grid Charger En/Dn, Operating Mode PCU/SMT/HYD Switches Reset for System ON/OFF, UP, DOWN, BACK, ENTER (for LCD Configuration) Indications System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD, Fault Degree of Protection IP21 Dimension (LxWxH) 609 X 330 X 660 mm Weight (Approx) 120 KG Product Description
Unique Features
Battery Selection Mode
In UTL's Alfa+ Solar PCU you have a great feature that is battery selection mode by this we can select any type of battery as per requirement i.e. flat plate/tubular/SMF/Lead acid Battery and can set charging voltage and charging current as per requirement.
Operating Mode Selection
PCU Mode - Priority Solar →Battery → Grid
Smart Mode -Priority Solar → Grid → Battery
Hybrid Mode - Priority for load Grid →Solar → Battery, Priority for battery charging Solar Energy → Grid
LCD Display with Energy Meter and Data Logging (optional)
UTL Alfa+ Solar PCU is also available with LCD display. This is an optional feature that can be availed by the customer for better user interface. When the customer opts for this feature, an energy meter and data logging facilities are also provided to the customer, which help the user to access information about the present and past status of the PCU functionality.
Pure Sine Wave
The output of the UTL's Alfa+ PCU is pure sine wave and it operates your appliances friendly.
User configurable by LCD
User friendly calibration settings:-
You can change the below settings of Alfa+ Solar PCU by itself like,
Configurable Grid Reconnect Setting
Configurable Battery Low cut Setting
Configurable Grid low cut/High cut setting
User friendly operational settings
No load shut down - Enable/Disable.
Grid charging - Enable/Disable.
IT Load - Enable/Disable.
Advanced features
- DSPic Based Pure Sine Wave Design.
- Inbuilt rMPPT Charge Controller.
- Maximum Preference to Solar Energy.
- USB Based Communication.
- 30 Days Data Logs Inbuilt
- AC and DC Energy Meter Inbuilt.
- GSM/GPRS Based Remote Monitoring and controlling.
- Robust Design for 20 years product life.
- 2 years to 5 years of warranty.
- Reverse AC Voltage Protection.
- User friendly and easily accessible LCD Display with all AC & DC Parameter Configurable by Display Switches and Digital LCD (20X4).
- User Friendly Control: - Output Voltage, Charging Voltage - SPV/ Grid, Charging Current - SPV/Grid, Grid Reconnect, Battery Low.
- Priority based working modes - Smart/PCU/Hybrid (for saving energy and money).
- NLSD, Alfa+Solar PCU Grid Charging, IT Load - Enable/Disable by LCD.